Cart and security cookies are required for the site to work. With your permission, we use Google Analytics and Microsoft Clarity to measure site usage, purchases and page interactions. Confirmed card purchases may also be measured from our server. Analytics is optional; advertising storage stays disabled.

You can change your choice from the footer. Cookie policy

● Türkiye's end-to-end solar energy partner
Ana içeriğe geç
● Ground-mount · MW-scale · International

Utility-Scale Solar Power Plant EPC in Turkey

Ground-mounted solar farms from hundreds of kWp to multi-megawatt, delivered turnkey for international developers and investors — with bankable feasibility and full grid-connection management.

Megawatt-scale ground-mounted solar farm in Turkey

Koru Energy delivers turnkey utility-scale solar power plants in Turkey — ground-mounted arrays from hundreds of kWp to multiple megawatts. Scope covers land and grid assessment, PVGIS-based yield and financial modelling, licensing, procurement of Tier-1 components, construction, grid connection, commissioning and long-term O&M.

Utility-scale EPC scope

Land & grid assessment

Site suitability, irradiation, topography and grid-capacity review before commitment.

Bankable feasibility

PVGIS yield, specific production, NPV/IRR/LCOE and payback for investment decisions.

Licensing & permits

Full regulatory process and connection agreement with the distribution/transmission operator.

Engineering & procurement

Array design, SLDs, Tier-1 bifacial modules, central/string inverters, MV equipment.

Construction & MV works

Piling/mounting, DC field, inverter stations, transformer and MV connection.

Commissioning & O&M

Energization, SCADA/monitoring, performance ratio testing and long-term O&M.

Mechanical & electrical installation pricing

Most MW-scale projects are contracted as installation works rather than full turnkey supply: the investor procures modules and inverters, and the mechanical and electrical works on site are awarded to a contractor. These are our indicative rates for that scope.

Plant typePer MWpPer kWp
Ground-mount$70,000 – $80,000$70 – $80
Rooftop$55,000 – $65,000$55 – $65

This is not a turnkey EPC price.

Modules and inverters are not included; total plant CAPEX is a multiple of this figure. Equipment prices move with brand and market, so we do not publish a single turnkey figure per MWp — ask us for a project-specific proposal instead.

Included

  • · Mounting structure assembly and module fixing
  • · Piling and foundation works on ground-mount sites (not applicable on rooftops)
  • · DC field cabling, string combining and cable trays
  • · AC side: switchgear, cabling and connection to the transformer/switchyard
  • · Earthing and lightning protection
  • · On-site mechanical and electrical labour

Not included

  • · Solar modules
  • · Inverters
  • · Transformer and MV switchgear
  • · Land, civil infrastructure and site landscaping
  • · Design, licensing, permits and grid-connection fees

Ground-mount runs roughly $15,000 per MWp above rooftop, mostly because of piling and foundation works — on a roof the building structure carries the array, though roof statics and waterproofing are assessed separately. Rates are quoted in US dollars, as MW-scale works in Turkey are priced in USD. Firm pricing follows a site survey and depends on ground conditions, array layout, cable runs and the distance to the grid connection point.

Why develop utility-scale solar in Turkey

Strong irradiation belts

Central/South-East Anatolia reach ~1,500–1,620 kWh/kWp/year — excellent for MW plants.

Bankable engineering

PVGIS-calibrated yield and documented design that stand up to investor due diligence.

Grid-connection expertise

We manage licensing and distribution/transmission connection end to end.

Tier-1 supply chain

Bifacial modules and reputable inverters at competitive, transparent pricing.

Single EPC contract

One accountable partner from land assessment to energization — no interface risk.

Lifecycle O&M

SCADA monitoring and maintenance to sustain performance ratio over 25+ years.

Utility-scale delivery process

  1. 1. Inquiry & requirements

    Share your site, target capacity, timeline and grid situation. We assign an English-speaking project manager as your single point of contact.

  2. 2. Feasibility & yield study

    Location-specific energy yield using PVGIS irradiation data, plus preliminary layout, CAPEX estimate and payback/IRR outline.

  3. 3. Proposal & contract

    A detailed turnkey proposal: scope, bill of materials, timeline, milestones and warranty terms.

  4. 4. Engineering & permits

    Detailed design (electrical, structural, SLD), licensing and distribution-company grid-connection applications.

  5. 5. Procurement & construction

    Tier-1 components, logistics, mounting, DC/AC works and safety-managed installation by our field teams.

  6. 6. Commissioning & handover

    Testing, grid energization, monitoring setup and documentation handover — your plant goes live.

  7. 7. Operation & maintenance

    Optional O&M: remote monitoring, scheduled maintenance, cleaning and performance reporting.

Frequently asked questions

What capacity range do you build?+

From a few hundred kWp up to multi-megawatt ground-mounted plants. We scope MV equipment and grid works to the target capacity and connection point.

Do you provide a bankable feasibility study?+

Yes — PVGIS-based energy yield, specific production, and financial metrics (NPV, IRR, LCOE, payback) suitable for investor and lender due diligence.

Can you manage licensing and grid connection?+

Yes. We handle the full regulatory process and the connection agreement with the distribution or transmission operator.

Which regions are best for utility-scale solar in Turkey?+

Central and South-Eastern Anatolia (e.g. Konya, Şanlıurfa) have the highest irradiation, typically ~1,500–1,620 kWh/kWp/year, but viable projects exist nationwide.

Do you use bifacial modules?+

Yes, where the ground albedo and layout justify it — bifacial modules can add roughly 5–10% yield on suitable sites.

Do you offer O&M for large plants?+

Yes — SCADA/remote monitoring, scheduled maintenance, cleaning and performance-ratio reporting under an O&M contract.

Request a utility-scale solar proposal

Share your land, target MW and grid situation. Our team replies within one business day with feasibility next steps.

Related solutions